Station#: ____________ Date (MM/DD/YY) _______/_______/________
Time of arrival (local time) ___________ Operator ________________
DAS number __________ Clock Type _________
Sensor type ________ Sensor number ______________
1. Install REFTEK and sensors
a. Dig a 2 ft. deep and 2 ft diameter hole (or less) for seismometers.
Level the sensors carefully. Orientation: channel 1 -> Vertical,
channel 2 -> magnetic north and channel 3 -> magnetic east.
b. Dig a 2.5 ft by 2.5 ft by 1.5 ft hole (less than 5 ft. away from the
sensor hole for environment purpose) for DAS, car battery and timing
device. Put battery in a trash bag, then put all in thick plastic bag
(4mm thick) toprotect the equipment from dirt and water.
2. Check battery voltage ___________(volts) (Must be 12V or high).
3. Connect battery -- DAS, DAS -- Sensor, DAS -- GPS (or Omega) and
DAS -- Hand
terminal. (Set up antenna for stations using OMEGA)
4. (optional) Receive parameters from DAS. Press COMMNCTNS/RECV PRMS.
Check if parameters
are correct. Send parameters back if you
have modified them
(Press COMMNCTNS/SEND PRMS).
5. (optional) Monitor. Press MONITOR. (to see if all the channels are Okay)
6. Bury the seismometer hole carefully. Do step 5 again.
7. System reset. Press UTILITIES/SYS RESET.
8. Start acquisition. Press COMMNCTNS/START ACQ. Zero delay time.
9. Look at DAS status and record below
TIME ________________
KIN OMGA __________
ACQ __________ ______(e.g. STAT ON)
EVENTS ____________
BLKS US ___________
BLKS AV ___________
10. Quit DAS status and Unplug HT or AT.
11. Bury the DAS hole carefully.
Time of Departure (local time) _________________________.
PLEASE NOTE ANY SPECIAL PROBLEMS ON THE BACK SIDE OF THIS SHEET.
Time of arrival (local time) ___________ Operator ________________
DAS # __________ Clock Type _________
1. Look for:
Signs of water pooling
in sensor hole. YES ____; NO _____.
Signs of animal intrusion.
YES _____; NO _____.
2. Check battery voltage _____________(volts).
3. Connect hand terminal (or field computer) and turn it on (Don't disturb the sensor).
(If voltage is low
and communication failure when press TIME, go to Step 6)
4. Check DAS status. Press UTILITIES/DAS STATE and record below
JULIAN DAY __________
TIME _____________
CLOCK _________________________(e.g. UTC LK PLL)
ACQ _________ _____(e.g. STRT
ON) EVENTS ________
BLKS US __________
BLKS AV ___________
5. Stop acquistion. Press COMMNCTNS/STOP ACQ and wait for FINISHED.
6. Swap DAS and battery. Connect battery--DAS, DAS--Sensor, DAS--GPS (or
Omega) and DAS--Hand terminal.
(Set up antenna for stations using OMEGA)
Be careful of polarity.
Red ( + ); Black ( - ).
Label old DAS immediately
with: Station #, DAS #, Year, Day #, and Operator
7. Check battery voltage ______________(volts) (Must be 12V or high).
8. New DAS# _____________
9. Monitor. Press MONITOR. (to see if all the channels are okay)
10. System reset. Press UTILITIES/SYS RESET.
11. Start acquisition. Press COMMNCTNS/STRT ACQ. Zero delay time.
12. Look at DAS status and record below
JULIAN DAY __________
TIME _____________
CLOCK _________________________(e.g. UTC LK PLL)
ACQ _________ _____(Must be
STRT ON) EVENTS __________
BLKS US __________
BLKS AV ___________
13. Quit DAS status and Unplug HT or AT.
14. Bury the DAS hole carefully.
Time of Departure (local time) _________________________.
PLEASE NOTE ANY SPECIAL PROBLEMS ON THE BACK SIDE OF THIS SHEET.
Time of arrival (local time) ___________ Operator ________________
DAS # __________ Clock Type _________
1. Look for:
Signs of water pooling
in sensor hole. YES ____; NO _____.
Signs of animal intrusion.
YES _____; NO _____.
2. Connect hand terminal (or field computer) and turn it on.
(If voltage is low
and communication failure when press TIME, go to Step 6)
3. Check DAS status. Press UTILITIES/DAS STATE and record below
JULIAN DAY __________
TIME _____________
CLOCK _________________________(e.g. UTC LK PLL)
ACQ _________ _____(e.g. STRT
ON) EVENTS ________
BLKS US __________
BLKS AV ___________
4. Stop acquistion. Press COMMNCTNS/STOP ACQ and wait for FINISHED.
Label DAS immediately
with: Station #, DAS #, Year, Day #, and Operator
5. Quit DAS status and Unplug HT or AT.
6. Pack up DAS (and disk) and battery.
7. Dig out sensors. Write down the sensor#__________________________________
Be sure to lock the sensors:
a). L4C-3D: place it 45
with handle at bottom.
b). UCLA L4C: place it verticallywith connection plug at bottom.
c). Others: no special locking
position.
Note: all the sensors should be protected by soft filling materials
when travelling.
8. Bury the holes carefully, clean up the surrounding. The original environment
should be recovered
completely.
Time of Departure (local time) _________________________.
PLEASE NOTE ANY SPECIAL PROBLEMS ON THE BACK SIDE OF THIS SHEET.